AN5800/80 Key Module
AN5800/80 Key Module
Classification:
Product Description
Technical Data
1. Sensor Requirements:
Eddy Current Sensor
Sensitivity: 8V/mm, ±1mm range;
Output Voltage Range: -2 to -18VDC;
GAP Voltage: -10VDC.
2. Output Signal:
Key Phase Output: TTL level signal digital output;
3. Module Power Supply:
DC Power Supply: 24VDC
Range: 18 to 36V
Power Consumption: less than 5W
4. Physical Characteristics:
Front Panel Size: (L×W×H)248mm×40mm×262mm 9.8in×1.5in×10.3in
Weight: 600g
Rear Panel Size: (L×W×H)128 mm×40mm×262mm 5in×1.5in×10.3in
Weight: 300g
5. Environmental Limitations:
Operating Temperature: -30℃ to +65℃ (-22oF to +150 oF)
Storage Temperature: -40℃ to +85℃ (-40oF to +180 oF)
Relative Humidity: 95% non-condensing
(Refer to execution standards)
(American Petroleum Institute API Standard 670;)
(Safety Certification: CE;)
(Electromagnetic Interference Resistance: EMC\ LVD;)
(Refer to EN55011\ EN61010\ EN50081\ EN50082.)
(Product Selection)
AN5800/80-AXX-BXX
(A: Channel Selection)
(00- Axis vibration and key phase)
(01- Amplitude and key phase)
(02- Eccentricity and key phase)
(03- Key phase)
(B: Sensor Selection)
(00—φ8 or φ5 Eddy Current Sensor)
(01—Magnetoresistive Sensor)
(C: Relay Output Selection)
(00—Three DPDT dry contact outputs (Alert, Danger, Not-ok))
(01—Two DPDT dry contact outputs (Alert, Danger))
(02—Single DPDT dry contact output (Alert))
(03—No relay output)
Previous Page
Next Page
Previous Page
Next Page
Related Products
Online message
* Note: Please be sure to fill in the information accurately and keep the communication unblocked. We will get in touch with you as soon as possible.