AN1811 eddy current sensor
AN1811 system
Classification:
Product Description
Technical Data
1. Measurement Range: 4mm (160mil) range
φ11 diameter probe; 5m/9m cable system, linear range: 1.00~5.00mm; GAP voltage: -10V (2.5mm), sensitivity: 3.94mV/μm (100 mV/mil);
2. Frequency Response:
0~10KHz, typical value is 0~-3dB.
3. Power Supply:
DC power supply: -24VDC (-20~-26VDC)
Power consumption: current consumption not exceeding 20mA
4. Requirements for the measured object:
The diameter of the measured object (width of the ring surface): not less than twice the diameter of the probe head; if the measured surface is smaller, calibration should be performed on-site.
Factory calibrated material for the measured object: 40CrMo steel / AISI4140 steel; if the material of the on-site measured object is inconsistent, calibration should be performed.
5. Interchangeability Error:
Interchangeable probes of the same model error ≤ ±5%;
Interchangeable extension cable error ≤ ±5%;
Interchangeable front-end device error ≤ ±5%;
6. On-site Wiring:
It is required to use a shielded three-core cable with a cross-section of 0.5~1.5mm², and the distance between the front-end device and monitor should be less than 300 meters (1000 feet).
7. Environmental Limitations:
8. Physical Characteristics:
Probe head material: Polyphenylene Sulfide (PPS);
Probe housing material: AISI304 stainless steel;
Probe head pressure resistance:12M,Pa
Extension cable:75Ω coaxial cable (plastic insulated outer skin wrapped);
Front-end device material:A308 cast aluminum.
Reference Execution Standards
American Petroleum Institute API670 standard;
Safety Certification: C E;
Protection Level: IP65;
Explosion-proof Level: ATEX:Ⅱ1 G ExiaⅡC T4
Electromagnetic Interference Resistance:EMC\ LVD
Refer to EN55011\ EN61010\EN50081\EN50082.
Product Selection
1.Probe Selection:
AN18XX-AXX-BXX-CXX-DXX-EXX-FXX
AN1805/08/11/25/40—φ5/φ8/φ11/φ25
Standard Configuration Model:
Axial Vibration Probe:AN1811/M-00-05-10-00-00-00
A:Range and Specifications:
05/M—2mm range, metric M8×1
05/I—2mm range, imperial1/4″-28UNF
08/M—2mm range, metric M10×1
08/I—2mm range, imperial3/8″-24UNF
08/MR—2mm range, reverse mounted metric M10×1
08/IR—2mm range, reverse mounted imperial3/8″-24UNF
11/M—4mm range, metric M14×1.5
11/I—4mm range, imperial1/2″-20UNF
11/MR—4mm range, metric M14×1.5
25/M—10mm量程,公制M30×2
25/ I—10mm量程,英制1 1/4″-12UNF
40/16—16mm量程,80×40矩形法兰安装
40/20—20mm量程,80×40矩形法兰安装
XX—其它
注:其它型号备注说明,详情咨询公司技术部
B:无螺纹长度:
00—0mm / 0 in
05—5mm/ 1/4 in
10—10mm/ 1/2 in
XX—其它
注:探头螺纹选择公制时无螺纹长度用mm表示;探头螺纹规格选择英制时以英寸in表示。无螺纹最长小于探头壳体
25mm/1in,反装探头无螺纹长度固定为5mm
C: Total length of the housing:
05—50mm / 2 in
10—100mm/4 in
03—30mm/ 1.2 in (dimensions of the reverse-mounted probe housing)
XX—其它
Note: The total length of the housing increases by 10mm / 0.5 in, with a maximum length of 250mm/10 in and a minimum of 30mm/1in.
D: Length of the probe with cable
05—0.5m
10—1m
50—5m
90—9m
E: Armored option
00—Non-armored
01—Armored
F: Approval agency
00—No requirements
01—Explosion-proof: EEx iall CT4
XX—其它
2. Extended cable selection:
AN1880-AXX-BXX-CXX-DXX
A: Cable length
40—4m
45—4.5m
80—8m
85—8.5m
B: Armored option
00—Non-armored
01—Armored
C: Approval agency
00—No requirements
(01) Explosion-proof: ExiallCT4.
XX—其它
(3) Front-end device selection:
(AN1800-AXX-BXX-CXX-DXX)
(A) Matching probe diameter.
(05) -5mm probe.
(08) -8mm probe.
(11) -11mm probe.
(25) -25mm probe.
XX—其它
(B) Total cable length (probe + extended cable).
(05)-5m.
(09)-9m.
(C): Installation method.
-DIN35mm rail installation.
-Base plate installation.
-Approval agency.
00—No requirements
(01) Explosion-proof: ExiallCT4.
XX—其它
Previous Page
Next Page
Previous Page
Next Page
Related Products
Online message
* Note: Please be sure to fill in the information accurately and keep the communication unblocked. We will get in touch with you as soon as possible.